Post-processing of the full matrix of ultrasonic transmit–receive array data for non-destructive evaluation C Holmes, BW Drinkwater, PD Wilcox NDT & e International 38 (8), 701-711, 2005 | 1303 | 2005 |
The post-processing of ultrasonic array data using the total focusing method C Holmes, B Drinkwater, P Wilcox Insight-Non-Destructive Testing and Condition Monitoring 46 (11), 677-680, 2004 | 188 | 2004 |
Advanced post-processing for scanned ultrasonic arrays: Application to defect detection and classification in non-destructive evaluation C Holmes, BW Drinkwater, PD Wilcox Ultrasonics 48 (6-7), 636-642, 2008 | 187 | 2008 |
Advanced reflector characterization with ultrasonic phased arrays in NDE applications PD Wilcox, C Holmes, BW Drinkwater IEEE transactions on ultrasonics, ferroelectrics, and frequency control 54 …, 2007 | 172 | 2007 |
Ultrasonic detection of surface-breaking railhead defects RS Edwards, C Holmes, Y Fan, M Papaelias, S Dixon, CL Davis, ... Insight-Non-Destructive Testing and Condition Monitoring 50 (7), 369-373, 2008 | 41 | 2008 |
Enhanced defect detection and characterisation by signal processing of ultrasonic array data PD Wilcox, C Holmes, BW Drinkwater Proc. 9th ECNDT, 2006 | 26 | 2006 |
Exploiting the Full Data Set from Ultrasonic Arrays by Post‐Processing PD Wilcox, C Holmes, BW Drinkwater AIP Conference Proceedings 820 (1), 845-852, 2006 | 26 | 2006 |
Post-processing of ultrasonic phased array data for optimal performance C Holmes, BW Drinkwater, PD Wilcox Insight-Non-Destructive Testing and Condition Monitoring 47 (2), 88-90, 2005 | 17 | 2005 |
11d-2 total focussing method for volumetric imaging in immersion non destructive evaluation A Tweedie, RL O'Leary, G Harvey, A Gachagan, C Holmes, PD Wilcox, ... 2007 IEEE Ultrasonics Symposium Proceedings, 1017-1020, 2007 | 13 | 2007 |
The mechanical behaviour and ultrasonic measurement of graphite joints C Holmes University of Bristol, 2003 | 5 | 2003 |
Signal processing of ultrasonic array data C Holmes, BW Drinkwater, PD Wilcox AIP Conference Proceedings 760 (1), 946-953, 2005 | 3 | 2005 |
Implementation of advanced array signal processing techniques in commercial array controller PD Wilcox, BW Drinkwater, C Holmes, A Velichko AIP Conference Proceedings 894 (1), 791-798, 2007 | 2 | 2007 |
The influence of interface effects on the rocking behaviour of graphite blocks C Holmes, BW Drinkwater, JFB Payne The Journal of Strain Analysis for Engineering Design 39 (4), 359-370, 2004 | 2 | 2004 |
The use of ultrasound to measure contact stiffness and pressure in large contacting interfaces C Holmes, BW Drinkwater AIP Conference Proceedings 657 (1), 1072-1079, 2003 | 2 | 2003 |
The use of ultrasound to measure contact stiffness and pressure distribution in large contacting interfaces C Holmes, BW Drinkwater NDT 2002, 39-44, 2002 | 1 | 2002 |
Application of total focussing method in immersion ultrasound non-destructive evaluation G Harvey, A Tweedie, C Holmes, PD Wilcox, R O'Leary, A Gachagan BINDT Annual Conference NDT 2007, 2007 | | 2007 |
Special Issue on High Resolution Ultrasonic Imaging in Industrial, Material and Biomaterial Applications-SPECIAL ISSUE PAPERS-Advanced Reflector Characterization with … PD Wilcox, C Holmes, BW Drinkwater IEEE Transactions on Ultrasonics Ferroelectrics and Frequency Control 54 (8 …, 2007 | | 2007 |
The measurement of the rocking behaviour of graphite bricks using ultrasound C Holmes, BW Drinkwater Proceedings of the Institution of Mechanical Engineers, Part C: Journal of …, 2004 | | 2004 |