Подписаться
Bernhard Laufer
Bernhard Laufer
Подтвержден адрес электронной почты в домене hs-furtwangen.de
Название
Процитировано
Процитировано
Год
Inertial sensor-based respiration analysis
G Karacocuk, F Höflinger, R Zhang, LM Reindl, B Laufer, K Möller, ...
IEEE Transactions on Instrumentation and Measurement 68 (11), 4268-4275, 2019
582019
Measurement of respiratory rate with inertial measurement units
S Beck, B Laufer, S Krueger-Ziolek, K Moeller
Current Directions in Biomedical Engineering 6 (3), 237-240, 2020
132020
Performance of variations of the dynamic elastance model in lung mechanics
B Laufer, PD Docherty, A Knörzer, YS Chiew, R Langdon, K Möller, ...
Control Engineering Practice 58, 262-267, 2017
132017
An alternative way to measure respiration induced changes of circumferences: a pilot study
B Laufer, S Krüger-Ziolek, PD Docherty, F Höflinger, L Reindl, K Möller
2020 42nd Annual International Conference of the IEEE Engineering in …, 2020
102020
Measuring lung mechanics of expiratory tidal breathing with non-invasive breath occlusion
SL Howe, M März, S Krüger-Ziolek, B Laufer, C Pretty, GM Shaw, ...
Biomedical engineering online 19 (1), 32, 2020
102020
Tidal volume via circumferences of the upper body: a pilot study
B Laufer, S Krüger-Ziolek, PD Docherty, F Höflinger, L Reindl, K Möller
2019 41st Annual International Conference of the IEEE Engineering in …, 2019
102019
Differences in respiratory mechanics estimation with respect to manoeuvres and mathematical models
J Kretschmer, C Bibiano, B Laufer, PD Docherty, YS Chiew, D Redmond, ...
Biomedical Physics & Engineering Express 3 (1), 014002, 2017
102017
A Minimal Set of Sensors in a Smart-Shirt to Obtain Respiratory Parameters
B Laufer, R Murray, PD Docherty, S Krueger-Ziolek, F Hoeflinger, L Reindl, ...
IFAC-PapersOnLine 53 (2), 16293-16298, 2020
92020
An Alternative Way to Measure Tidal Volumes
B Laufer, S Krueger-Ziolek, PD Docherty, F Hoeflinger, L Reindl, ...
European Medical and Biological Engineering Conference, 66-72, 2020
82020
Laparoscopic video analysis using temporal, attention, and multi-feature fusion based-approaches
NA Jalal, TA Alshirbaji, PD Docherty, H Arabian, B Laufer, ...
Sensors 23 (4), 1958, 2023
52023
Analysing multi-perspective patient-related data during laparoscopic gynaecology procedures
NA Jalal, T Abdulbaki Alshirbaji, B Laufer, PD Docherty, T Neumuth, ...
Scientific reports 13 (1), 1604, 2023
52023
Characterisation and Quantification of Upper Body Surface Motions for Tidal Volume Determination in Lung-Healthy Individuals
B Laufer, F Hoeflinger, PD Docherty, NA Jalal, S Krueger-Ziolek, ...
Sensors 23 (3), 1278, 2023
52023
Sensor placement in a smart compression shirt to measure spontaneous breathing
B Laufer, J Kretschmer, PD Docherty, K Möller, F Höflinger, L Reindl
Biomedical Engineering/Biomedizinische Technik 62 (S1), S127, 2017
52017
Effects of intra-abdominal pressure on lung mechanics during laparoscopic gynaecology
NA Jalal, TA Alshirbaji, B Laufer, PD Docherty, SG Russo, T Neumuth, ...
2021 43rd Annual International Conference of the IEEE Engineering in …, 2021
42021
Changes of Physiological parameters of the patient during laparoscopic gynaecology
NA Jalal, TA Alshirbaji, PD Docherty, T Neumuth, B Laufer, K Moeller
Current Directions in Biomedical Engineering 7 (2), 500-503, 2021
32021
A method for observing ongoing patient respiratory behaviour with the NARX model
PD Docherty, T Lerios, B Laufer, K Moeller, G Chase
32020
Impact of lung volume changes on perfusion estimates derived by Electrical Impedance Tomography
S Krueger-Ziolek, B Gong, B Laufer, K Moeller
Current Directions in Biomedical Engineering 5 (1), 199-202, 2019
32019
Minimum number of sensors in a smart shirt to measure tidal volumes
B Laufer, S Krüger-Ziolek, PD Docherty, F Höflinger, L Reindl, K Möller
IFAC-PapersOnLine 51 (27), 92-97, 2018
32018
Sensor selection for tidal volume determination via regression–proof of methodology
B Laufer, NA Jalal, PD Docherty, S Krüger-Ziolek, F Hoeflinger, L Reindl, ...
Proceedings on Automation in Medical Engineering 2 (1), 734-734, 2023
22023
Optimal Sensor Location in a Smart-Shirt to Measure Accurate Tidal Volumes During Abdominal and Thoracic Respiration
B Laufer, PD Docherty, R Murray, NA Jalal, F Hoeflinger, L Reindl, ...
Current Directions in Biomedical Engineering 7 (2), 574-577, 2021
22021
В данный момент система не может выполнить эту операцию. Повторите попытку позднее.
Статьи 1–20