Toward imaging the body at 10.5 tesla MA Ertürk, X Wu, Y Eryaman, PF Van de Moortele, EJ Auerbach, ... Magnetic resonance in medicine 77 (1), 434-443, 2017 | 138 | 2017 |
Reduction of implant RF heating through modification of transmit coil electric field Y Eryaman, B Akin, E Atalar Magnetic resonance in medicine 65 (5), 1305-1313, 2011 | 119 | 2011 |
In vivo human head MRI at 10.5 T: A radiofrequency safety study and preliminary imaging results A Sadeghi‐Tarakameh, L DelaBarre, RL Lagore, A Torrado‐Carvajal, ... Magnetic resonance in medicine 84 (1), 484-496, 2020 | 96 | 2020 |
Parallel transmit pulse design for patients with deep brain stimulation implants Y Eryaman, B Guerin, C Akgun, JL Herraiz, A Martin, A Torrado‐Carvajal, ... Magnetic resonance in medicine 73 (5), 1896-1903, 2015 | 93 | 2015 |
Transcranial focused ultrasound for BOLD fMRI signal modulation in humans L Ai, JK Mueller, A Grant, Y Eryaman, W Legon 2016 38th Annual International Conference of the IEEE Engineering in …, 2016 | 80 | 2016 |
First in‐vivo human imaging at 10.5 T: Imaging the body at 447 MHz X He, MA Ertürk, A Grant, X Wu, RL Lagore, L DelaBarre, Y Eryaman, ... Magnetic resonance in medicine 84 (1), 289-303, 2020 | 78 | 2020 |
Reduction of the radiofrequency heating of metallic devices using a dual‐drive birdcage coil Y Eryaman, EA Turk, C Oto, O Algin, E Atalar Magnetic resonance in medicine 69 (3), 845-852, 2013 | 77 | 2013 |
Fast electromagnetic analysis of MRI transmit RF coils based on accelerated integral equation methods JF Villena, AG Polimeridis, Y Eryaman, E Adalsteinsson, LL Wald, ... IEEE Transactions on Biomedical Engineering 63 (11), 2250-2261, 2016 | 74 | 2016 |
Miniaturized fiber‐optic transmission system for MRI signals OG Memis, Y Eryaman, O Aytur, E Atalar Magnetic Resonance in Medicine: An Official Journal of the International …, 2008 | 45 | 2008 |
10.5 T MRI static field effects on human cognitive, vestibular, and physiological function A Grant, GJ Metzger, PF Van de Moortele, G Adriany, C Olman, L Zhang, ... Magnetic resonance imaging 73, 163-176, 2020 | 42 | 2020 |
A simple geometric analysis method for measuring and mitigating RF induced currents on deep brain stimulation leads by multichannel transmission/reception Y Eryaman, N Kobayashi, S Moen, J Aman, A Grant, JT Vaughan, ... Neuroimage 184, 658-668, 2019 | 42 | 2019 |
Magnetic resonance method and apparatus for reducing RF heating in the patient Y Eryaman, E Atalar US Patent 8,319,496, 2012 | 39 | 2012 |
SAR reduction in 7T C‐spine imaging using a “dark modes” transmit array strategy Y Eryaman, B Guerin, B Keil, A Mareyam, JL Herraiz, RK Kosior, A Martin, ... Magnetic resonance in medicine 73 (4), 1533-1539, 2015 | 38 | 2015 |
Multi‐atlas and label fusion approach for patient‐specific MRI based skull estimation A Torrado‐Carvajal, JL Herraiz, JA Hernandez‐Tamames, ... Magnetic resonance in medicine 75 (4), 1797-1807, 2016 | 33 | 2016 |
Evaluation of internal MRI coils using ultimate intrinsic SNR H Çelik, Y Eryaman, A Altıntaş, IA Abdel‐Hafez, E Atalar Magnetic Resonance in Medicine: An Official Journal of the International …, 2004 | 32 | 2004 |
Improving radiofrequency power and specific absorption rate management with bumped transmit elements in ultra‐high field MRI A Sadeghi‐Tarakameh, G Adriany, GJ Metzger, RL Lagore, S Jungst, ... Magnetic resonance in medicine 84 (6), 3485-3493, 2020 | 28 | 2020 |
Comparison of 16-channel asymmetric sleeve antenna and dipole antenna transceiver arrays at 10.5 Tesla MRI MK Woo, L Delabarre, M Waks, J Lee, RL Lagore, S Jungst, A Grant, ... IEEE transactions on medical imaging 40 (4), 1147-1156, 2020 | 20 | 2020 |
Evaluation of a 16-channel transceiver loop+ dipole antenna array for human head imaging at 10.5 tesla MK Woo, L Delabarre, BY Lee, M Waks, RL Lagore, JW Radder, ... IEEE Access 8, 203555-203563, 2020 | 19 | 2020 |
Radiofrequency heating studies on anesthetized swine using fractionated dipole antennas at 10.5 T Y Eryaman, RL Lagore, MA Ertürk, L Utecht, P Zhang, A Torrado‐Carvajal, ... Magnetic resonance in medicine 79 (1), 479-488, 2018 | 19 | 2018 |
Design of internal MRI coils using ultimate intrinsic SNR Y Eryaman, Y Öner, E Atalar Magnetic Resonance Materials in Physics, Biology and Medicine 22, 221-228, 2009 | 18 | 2009 |