Follow
Michael Todd
Michael Todd
Professor of Structural Engineering, University of California San Diego
Verified email at ucsd.edu - Homepage
Title
Cited by
Cited by
Year
Energy harvesting for structural health monitoring sensor networks
G Park, T Rosing, MD Todd, CR Farrar, W Hodgkiss
Journal of Infrastructure Systems 14 (1), 64-79, 2008
5772008
A Bayesian approach to optimal sensor placement for structural health monitoring with application to active sensing
EB Flynn, MD Todd
Mechanical Systems and Signal Processing 24 (4), 891-903, 2010
3022010
Development of an impedance-based wireless sensor node for structural health monitoring
DL Mascarenas, MD Todd, G Park, CR Farrar
Smart Materials and Structures 16 (6), 2137, 2007
2622007
Flexural beam-based fiber Bragg grating accelerometers
MD Todd, GA Johnson, BA Althouse, ST Vohra
IEEE Photonics Technology Letters 10 (11), 1605-1607, 1998
2511998
A review of nonlinear dynamics applications to structural health monitoring
K Worden, CR Farrar, J Haywood, M Todd
Structural Control and Health Monitoring: The Official Journal of the …, 2008
2422008
Maximum-likelihood estimation of damage location in guided-wave structural health monitoring
EB Flynn, MD Todd, PD Wilcox, BW Drinkwater, AJ Croxford
Proceedings of the Royal Society A: Mathematical, Physical and Engineering …, 2011
1832011
Sensor network paradigms for structural health monitoring
CR Farrar, G Park, DW Allen, MD Todd
Structural Control and Health Monitoring: The Official Journal of the …, 2006
1682006
Vibration-based damage assessment utilizing state space geometry changes: local attractor variance ratio
MD Todd, JM Nichols, LM Pecora, LN Virgin
Smart Materials and Structures 10 (5), 1000, 2001
1622001
Use of chaotic excitation and attractor property analysis in structural health monitoring
JM Nichols, MD Todd, M Seaver, LN Virgin
Physical Review E 67 (1), 016209, 2003
1382003
A novel Bragg grating sensor interrogation system utilizing a scanning filter, a Mach-Zehnder interferometer and a 3× 3 coupler
MD Todd, GA Johnson, BL Althouse
Measurement science and technology 12 (7), 771, 2001
1352001
A mobile host approach for wireless powering and interrogation of structural health monitoring sensor networks
D Mascarenas, E Flynn, C Farrar, G Park, M Todd
IEEE Sensors Journal 9 (12), 1719-1726, 2009
1192009
Optimal placement of piezoelectric actuators and sensors for detecting damage in plate structures
EB Flynn, MD Todd
Journal of Intelligent Material Systems and Structures 21 (3), 265-274, 2010
1162010
Bragg grating-based fibre optic sensors in structural health monitoring
MD Todd, JM Nichols, ST Trickey, M Seaver, CJ Nichols, LN Virgin
Philosophical Transactions of the Royal Society A: Mathematical, Physical …, 2007
1142007
A mobile-agent-based wireless sensing network for structural monitoring applications
SG Taylor, KM Farinholt, EB Flynn, E Figueiredo, DL Mascarenas, ...
Measurement Science and Technology 20 (4), 045201, 2009
1122009
Improved, operationally-passive interferometric demodulation method using 3× 3 coupler
MD Todd, M Seaver, F Bucholtz
Electronics Letters 38 (15), 1, 2002
1102002
Passive, light intensity-independent interferometric method for fibre Bragg grating interrogation
MD Todd, GA Johnson, CC Chang
Electronics Letters 35 (22), 1970-1971, 1999
1101999
Isogeometric fatigue damage prediction in large-scale composite structures driven by dynamic sensor data
Y Bazilevs, X Deng, A Korobenko, F Lanza di Scalea, MD Todd, ...
Journal of Applied Mechanics 82 (9), 091008, 2015
1092015
Using state space predictive modeling with chaotic interrogation in detecting joint preload loss in a frame structure experiment
JM Nichols, MD Todd, JR Wait
Smart Materials and Structures 12 (4), 580, 2003
1042003
Structural health monitoring through chaotic interrogation
JM Nichols, ST Trickey, MD Todd, LN Virgin
Meccanica 38, 239-250, 2003
952003
Deployment of a fiber Bragg grating-based measurement system in a structural health monitoring application
MD Todd, GA Johnson, ST Vohra
Smart materials and structures 10 (3), 534, 2001
922001
The system can't perform the operation now. Try again later.
Articles 1–20