Подписаться
Heming Zhen, PhD
Heming Zhen, PhD
Boston Medical Center
Подтвержден адрес электронной почты в домене bmc.org
Название
Процитировано
Процитировано
Год
Per‐beam, planar IMRT QA passing rates do not predict clinically relevant patient dose errors
BE Nelms, H Zhen, WA Tomé
Medical physics 38 (2), 1037-1044, 2011
4972011
Moving from gamma passing rates to patient DVH‐based QA metrics in pretreatment dose QA
H Zhen, BE Nelms, WA Tomé
Medical physics 38 (10), 5477-5489, 2011
3092011
Dosimetric comparison of Acuros XB with collapsed cone convolution/superposition and anisotropic analytic algorithm for stereotactic ablative radiotherapy of thoracic spinal …
H Zhen, B Hrycushko, H Lee, R Timmerman, A Pompoš, S Stojadinovic, ...
Journal of applied clinical medical physics 16 (4), 181-192, 2015
372015
On the use of biomathematical models in patient‐specific IMRT dose QA
H Zhen, BE Nelms, WA Tomé
Medical physics 40 (7), 071702, 2013
232013
A model for predicting the dose to the parotid glands based on their relative overlapping with planning target volumes during helical radiotherapy
CH Millunchick, H Zhen, G Redler, Y Liao, JV Turian
Journal of Applied Clinical Medical Physics 19 (2), 48-53, 2018
152018
Automated extraction of dose/volume statistics for radiotherapy-treatment-plan evaluation in clinical-trial quality assurance
YUT Gong, J Yu, D Pang, H Zhen, J Galvin, Y Xiao
Frontiers in Oncology 6, 47, 2016
82016
Dosimetric effects of saline-versus water-filled balloon applicators for IORT using the model S700 electronic brachytherapy source
G Redler, A Templeton, H Zhen, J Turian, D Bernard, JCH Chu, KL Griem, ...
Brachytherapy 17 (2), 500-505, 2018
72018
Initial clinical experience using a novel Pd-103 surface applicator for the treatment of retroperitoneal and abdominal wall malignancies
H Zhen, JV Turian, N Sen, MB Luu, RA Abrams, D Wang
Advances in Radiation Oncology 3 (2), 216-220, 2018
42018
Interfraction tumor size changes during lung SBRT: What factors matter?
K King, S Mayekar, G Marwaha, G Tolekidis, G Cifter, H Zhen
International Journal of Radiation Oncology, Biology, Physics 99 (2), E469-E470, 2017
22017
WE‐C‐BRB‐12: Moving from gamma based to patient DVH based IMRT QA
H Zhen, BE Nelms, WA Tomé
Medical Physics 38 (6Part32), 3806-3807, 2011
22011
The step‐and‐shoot IMRT overshooting phenomenon: a novel method to mitigate patient overdosage
H Zhen, L Ouyang, Q Bao, N Qin, S Stojadinovic, A Pompos
Journal of applied clinical medical physics 17 (4), 214-222, 2016
12016
Evaluation of Acuros XB for SAbR Planning of Thoracic Spinal Tumors
H Zhen, B Hrycushko, A Pompoš, R Foster, Y Yan, S Stojadinovic, ...
International Journal of Radiation Oncology, Biology, Physics 87 (2), S733, 2013
12013
Improving Patient-Specific Pre-Treatment Quality Assurance
H Zhen
The University of Wisconsin-Madison, 2012
12012
SU‐GG‐T‐195: On the Correlation of Conventional IMRT QA Metrics to Clinical Impact in Per‐Patient Dose QA
H Zhen, B Nelms, W Tome
Medical Physics 37 (6Part18), 3229-3230, 2010
12010
SU‐GG‐T‐184: Per‐Patient Dose QA Based on Clinically Relevant Metrics: Validation of the Planned Dose Perturbation Method to Estimate Patient Dose/DVH Using Conventional QA Data
B Nelms, H Zhen, D Savitskij, R Hardee, W Tome
Medical Physics 37 (6Part18), 3227-3227, 2010
12010
Is Mean Radiation Dose to the Subventricular Zone a Prognostic Indicator?
PA Blumenfeld, G Tolekidis, H Zhen, M Guryildirim, J Shin, D Chan, ...
International Journal of Radiation Oncology, Biology, Physics 99 (2), E66, 2017
2017
Dosimetric Characteristics of the CivaDota, cent Unidirectional Pd-103 Brachytherapy Source
H Zhen, G Redler, Y Liao
MEDICAL PHYSICS 44 (6), 3193-3193, 2017
2017
SU‐E‐T‐381: The Step‐And‐Shoot IMRT Overshooting Phenomena: A Novel Method to Mitigate Patient Overdosage
A Pompos, H Zhen, L Ouyang, Q Bao, S Stojadinovic
Medical Physics 40 (6Part16), 292-292, 2013
2013
SU‐E‐T‐556: Verification and Evaluation of Acuros XB Dose Calculations for Stereotactic Ablative Radiotherapy of the Thoracic Spine
H Zhen, B Hrycushko, A Pompos, R Foster, Y Yan, S Stojadinovic, ...
Medical Physics 40 (6Part19), 333-333, 2013
2013
The Impact of TPS and Machine Delivery Errors on Clinical Outcomes as Estimated by Biological Models
H Zhen, BE Nelms, WA Tomé
International Journal of Radiation Oncology, Biology, Physics 84 (3), S130, 2012
2012
В данный момент система не может выполнить эту операцию. Повторите попытку позднее.
Статьи 1–20