Follow
Christopher L. Hendrickson
Christopher L. Hendrickson
National High Magnetic Field Laboratory
Verified email at magnet.fsu.edu
Title
Cited by
Cited by
Year
Fourier transform ion cyclotron resonance mass spectrometry: a primer
AG Marshall, CL Hendrickson, GS Jackson
Mass spectrometry reviews 17 (1), 1-35, 1998
25801998
Kendrick mass defect spectrum: a compact visual analysis for ultrahigh-resolution broadband mass spectra
CA Hughey, CL Hendrickson, RP Rodgers, AG Marshall, K Qian
Analytical chemistry 73 (19), 4676-4681, 2001
7812001
External accumulation of ions for enhanced electrospray ionization Fourier transform ion cyclotron resonance mass spectrometry
MW Senko, CL Hendrickson, MR Emmett, SDH Shi, AG Marshall
Journal of the American Society for Mass Spectrometry 8 (9), 970-976, 1997
5431997
High-resolution mass spectrometers
AG Marshall, CL Hendrickson
Annual review of analytical chemistry 1 (1), 579, 2008
4222008
Reading chemical fine print: Resolution and identification of 3000 nitrogen-containing aromatic compounds from a single electrospray ionization Fourier transform ion cyclotron …
K Qian, RP Rodgers, CL Hendrickson, MR Emmett, AG Marshall
Energy & fuels 15 (2), 492-498, 2001
3952001
Free electron laser-Fourier transform ion cyclotron resonance mass spectrometry facility for obtaining infrared multiphoton dissociation spectra of gaseous ions
JJ Valle, JR Eyler, J Oomens, DT Moore, AFG Van Der Meer, ...
Review of Scientific Instruments 76 (2), 023103, 2005
3112005
Atmospheric pressure photoionization Fourier transform ion cyclotron resonance mass spectrometry for complex mixture analysis
JM Purcell, CL Hendrickson, RP Rodgers, AG Marshall
Analytical Chemistry 78 (16), 5906-5912, 2006
3032006
Fourier transform ion cyclotron resonance detection: principles and experimental configurations
AG Marshall, CL Hendrickson
International Journal of Mass Spectrometry 215 (1-3), 59-75, 2002
2972002
Probing protein ligand interactions by automated hydrogen/deuterium exchange mass spectrometry
MJ Chalmers, SA Busby, BD Pascal, Y He, CL Hendrickson, AG Marshall, ...
Analytical chemistry 78 (4), 1005-1014, 2006
2902006
Electrospray ionization Fourier transform ion cyclotron resonance at 9.4 T
MW Senko, CL Hendrickson, L Paša‐Tolić, JA Marto, FM White, S Guan, ...
Rapid Communications in Mass Spectrometry 10 (14), 1824-1828, 1996
2791996
High resolution mass spectrometry
F Xian, CL Hendrickson, AG Marshall
Analytical chemistry 84 (2), 708-719, 2012
2682012
Combined electron capture and infrared multiphoton dissociation for multistage MS/MS in a Fourier transform ion cyclotron resonance mass spectrometer
K Håkansson, MJ Chalmers, JP Quinn, MA McFarland, CL Hendrickson, ...
Analytical chemistry 75 (13), 3256-3262, 2003
2652003
Comparison and interconversion of the two most common frequency-to-mass calibration functions for Fourier transform ion cyclotron resonance mass spectrometry
SDH Shi, JJ Drader, MA Freitas, CL Hendrickson, AG Marshall
International Journal of Mass Spectrometry 195, 591-598, 2000
2572000
A novel 9.4 Tesla FTICR mass spectrometer with improved sensitivity, mass resolution, and mass range
NK Kaiser, JP Quinn, GT Blakney, CL Hendrickson, AG Marshall
Journal of the American Society for Mass Spectrometry 22 (8), 1343-1351, 2011
2352011
High-performance mass spectrometry: Fourier transform ion cyclotron resonance at 14.5 Tesla
TM Schaub, CL Hendrickson, S Horning, JP Quinn, MW Senko, ...
Analytical chemistry 80 (11), 3985-3990, 2008
2322008
Predator data station: A fast data acquisition system for advanced FT-ICR MS experiments
GT Blakney, CL Hendrickson, AG Marshall
International Journal of Mass Spectrometry 306 (2-3), 246-252, 2011
2302011
Sulfur speciation in petroleum: Atmospheric pressure photoionization or chemical derivatization and electrospray ionization Fourier transform ion cyclotron resonance mass …
JM Purcell, P Juyal, DG Kim, RP Rodgers, CL Hendrickson, AG Marshall
Energy & Fuels 21 (5), 2869-2874, 2007
2152007
Application of micro-electrospray liquid chromatography techniques to FT-ICR MS to enable high-sensitivity biological analysis
MR Emmett, FM White, CL Hendrickson, SDH Shi, AG Marshall
Journal of the American Society for Mass Spectrometry 9 (4), 333-340, 1998
2081998
Elemental composition analysis of processed and unprocessed diesel fuel by electrospray ionization Fourier transform ion cyclotron resonance mass spectrometry
CA Hughey, CL Hendrickson, RP Rodgers, AG Marshall
Energy & Fuels 15 (5), 1186-1193, 2001
2032001
Parts-per-billion Fourier transform ion cyclotron resonance mass measurement accuracy with a “walking” calibration equation
JJ Savory, NK Kaiser, AM McKenna, F Xian, GT Blakney, RP Rodgers, ...
Analytical chemistry 83 (5), 1732-1736, 2011
2002011
The system can't perform the operation now. Try again later.
Articles 1–20