Подписаться
David A. Scaduto
David A. Scaduto
Подтвержден адрес электронной почты в домене stonybrook.edu - Главная страница
Название
Процитировано
Процитировано
Год
Comparison of contrast-enhanced digital mammography and contrast-enhanced digital breast tomosynthesis for lesion assessment
H Huang, DA Scaduto, C Liu, J Yang, C Zhu, K Rinaldi, J Eisenberg, J Liu, ...
Journal of medical imaging 6 (3), 031407-031407, 2019
342019
A scatter correction method for contrast-enhanced dual-energy digital breast tomosynthesis
Y Lu, B Peng, BA Lau, YH Hu, DA Scaduto, W Zhao, G Gindi
Physics in Medicine & Biology 60 (16), 6323, 2015
292015
Optimization of contrast‐enhanced breast imaging: analysis using a cascaded linear system model
YH Hu, DA Scaduto, W Zhao
Medical Physics 44 (1), 43-56, 2017
252017
Experimental Characterization of a Direct Conversion Amorphous Selenium Detector with Thicker Conversion Layer for Dual‐Energy Contrast‐Enhanced Breast Imaging
DA Scaduto, O Tousignant, W Zhao
Medical Physics, 2017
162017
Optimization of clinical protocols for contrast enhanced breast imaging
YH Hu, DA Scaduto, W Zhao
Medical Imaging 2013: Physics of Medical Imaging 8668, 98-106, 2013
162013
Dependence of contrast-enhanced lesion detection in contrast-enhanced digital breast tomosynthesis on imaging chain design
DA Scaduto, YH Hu, Y Lu, H Huang, J Liu, K Rinaldi, G Gindi, PR Fisher, ...
Breast Imaging: 13th International Workshop, IWDM 2016, Malmö, Sweden, June …, 2016
142016
Application of the ordered-subsets transmission reconstruction algorithm to contrast-enhanced dual-energy digital breast tomosynthesis
Y Lu, B Peng, DA Scaduto, W Zhao, G Gindi
2014 IEEE Nuclear Science Symposium and Medical Imaging Conference (NSS/MIC …, 2014
102014
The effect of amorphous selenium thickness on imaging performance of contrast enhanced digital breast tomosynthesis
YH Hu, DA Scaduto, W Zhao
Breast Imaging: 11th International Workshop, IWDM 2012, Philadelphia, PA …, 2012
92012
Impact of angular range of digital breast tomosynthesis on mass detection in dense breasts
DA Scaduto, H Huang, C Liu, K Rinaldi, A Hebecker, T Mertelmeier, ...
14th International Workshop on Breast Imaging (IWBI 2018) 10718, 490-499, 2018
82018
Lesion assessment and radiation dose in contrast-enhanced digital breast tomosynthesis
H Huang, DA Scaduto, C Liu, J Yang, C Zhu, K Rinaldi, J Eisenberg, J Liu, ...
14th International Workshop on Breast Imaging (IWBI 2018) 10718, 405-410, 2018
52018
Determination of system geometrical parameters and consistency between scans for contrast-enhanced digital breast tomosynthesis
DA Scaduto, W Zhao
Breast Imaging: 11th International Workshop, IWDM 2012, Philadelphia, PA …, 2012
42012
WE‐DE‐207B‐05: Measuring Spatial Resolution in Digital Breast Tomosynthesis: Update of AAPM Task Group 245
DA Scaduto, M Goodsitt, HP Chan, H Olafsdottir, M Das, E Fredenberg, ...
Medical Physics 43 (6Part40), 3818-3818, 2016
32016
Clinically translating contrast-enhanced x-ray breast imaging
DA Scaduto
State University of New York at Stony Brook, 2017
22017
Investigation of spatial resolution and temporal performance of SAPHIRE (scintillator avalanche photoconductor with high resolution emitter readout) with integrated …
DA Scaduto, AR Lubinsky, JA Rowlands, H Kenmotsu, N Nishimoto, ...
Medical Imaging 2014: Physics of Medical Imaging 9033, 1086-1094, 2014
22014
Comparison of lesion detection and conspicuity between narrow-angle and wide-angle digital breast tomosynthesis for dense and non-dense breasts
H Huang, D Scaduto, A Plaunova, K Rinaldi, PR Fisher, W Zhao
Journal of Medical Imaging 10 (S2), S22407-S22407, 2023
12023
Effects of angular range on lesion margin assessment in contrast-enhanced digital breast tomosynthesis
H Huang, DA Scaduto, K Rinaldi, J Liu, J Wicklein, M Hoernig, ...
Medical Imaging 2019: Physics of Medical Imaging 10948, 971-978, 2019
2019
Digital breast tomosynthesis with minimal breast compression
DA Scaduto, M Yang, J Ripton-Snyder, PR Fisher, W Zhao
Medical Imaging 2015: Physics of Medical Imaging 9412, 474-485, 2015
2015
TU‐F‐18C‐02: Increasing Amorphous Selenium Thickness in Direct Conversion Flat‐Panel Imagers for Contrast‐Enhanced Dual‐Energy Breast Imaging
DA Scaduto, YH Hu, W Zhao
Medical Physics 41 (6Part28), 478-478, 2014
2014
В данный момент система не может выполнить эту операцию. Повторите попытку позднее.
Статьи 1–18